Test Procedure
-- Observe safety precautions. Refer to SAFETY PRECAUTIONS
-- Observe Clean Working Conditions. Refer to CLEAN WORKING CONDITIONS
-- Perform a preliminary check to verify the customers complaint. Refer to PRELIMINARY CHECK .
Start Diagnosis
-- Connect scan tool.
-- Start the engine and let idle.
-- Perform the function test located in diagnostic mode 06. Refer to DIAGNOSTIC MODE 06 - READ TEST RESULTS FOR SPECIFIC DIAGNOSTIC FUNCTIONS .
If specified values are obtained:
-- Fault may be intermittent.
-- Check for loose or corroded connections and any leaks in the exhaust.
-- Check Freeze Frame data for conditions when the DTC set.
-- Go to Final procedures
If the specified values are not obtained:
-- Disconnect the HO2S Oxygen Sensor Bank 1 Sensor 1 -G39- electrical harness connector.
Checking voltages
-- Switch the ignition ON.
-- Using a Multimeter, check the Heated Oxygen Sensor (HO2S) -G39- electrical harness connector terminals 2 to 6 for voltage.
Specified value: 0.400 to 0.500 Volts
-- Switch the ignition OFF.
If the specified values were obtained:
-- Replace the HO2S Oxygen Sensor Bank 1 Sensor 1 -G39-. Refer to the Repair Information.
If the specified value was obtained: