Checking Ground
-- Using a multimeter, check the Secondary Air Injection (SAI) Pump Motor --V101-- electrical harness connector terminal 1 to Ground for resistance.
Specified value: 1.5 Ω Max.
If the specified value was Not obtained:
-- Check the wiring for an open or high resistance.
-- Check the electrical harness connector for damage, corrosion, loose or broken terminals.
-- If necessary, repair the faulty wiring connection.
If no malfunction is found in the wiring and voltage supply was OK:
-- Replace Secondary Air Injection (SAI) Pump Motor --V101--.
-- Erase the DTC memory. Refer to DIAGNOSTIC MODE 04 - ERASE DTC MEMORY .
-- Perform a road test to verify repair.