Test Procedure
-- Perform a preliminary check to verify the customers complaint. Refer to PRELIMINARY CHECK
Start diagnosis
NOTE:
Before disconnecting the Knock Sensor electrical harness connectors, mark the component location.
-- Disconnect the green Knock Sensor (KS) 1 -G61- electrical harness connector -1-.
Checking internal resistance
-- Using a multimeter, check the Knock Sensor terminals 1 to 2 for an internal short.
Specified value: ∞ (Infinity) or OL reading.
If the specified value was Not obtained:
-- Replace the faulty Knock Sensor (KS) 1 -G61-. Refer to the Repair Information.
If the specified value was obtained: