Test Procedure For Fuel Pump
-- Remove the floor sealing cover to access the Fuel Delivery Unit (fuel pump).
-- Disconnect the harness connector from the Fuel Delivery Unit.
-- Connect the multimeter positive lead to terminal -1- of the Fuel Delivery Unit harness connector.
-- Connect the multimeter ground lead to terminal -5- of the Fuel Delivery Unit harness connector.
-- Crank the engine and note voltage displayed on multimeter during crank. Voltage should be within 2.5 volts of battery voltage.
-- If voltage is below specification, replace the Fuel Pump Control Module.
-- If voltage is within specification, replace the Fuel Delivery Unit (Fuel Pump). Refer to the Repair Information.