Home >> Volkswagen >> 2011 >> Jetta Base >> Repair and Diagnosis >> Engine Performance >> System >> 2.0L - Generic Scan Tool - Engine Code: CBPA (Sedan) >> St Generic Scan Tool >> Diagnosis And Testing >> Diagnostic Procedures >> Heated Oxygen Sensor Heater After Three Way Catalytic Converter, Checking
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Heated Oxygen Sensor Heater After Three Way Catalytic Converter, Checking

NOTE:

Vehicle must be raised before electrical harness connector for the Oxygen Sensor After Three Way Catalytic Converter -G130- / Heater For Oxygen Sensor 1 After Catalytic Converter -Z29- is accessible.

When servicing terminals in harness connectors, use only gold-plated terminals.

Special tools and workshop equipment required 

Test requirements 

Test procedure 

-- Perform a preliminary check to verify the customers complaint. Refer to PRELIMINARY CHECK 

Start diagnosis 

-- Remove the right vehicle floor cover.

Checking internal resistance 

-- Disconnect the Oxygen Sensor After Three Way Catalytic Converter -G130- / Heater For Oxygen Sensor 1 After Catalytic Converter -Z29- electrical harness connector.

-- Using a multimeter, check the Oxygen Sensor After Three Way Catalytic Converter -G130- / Heater For Oxygen Sensor 1 After Catalytic Converter -Z29- electrical harness connector terminals 1 to 2 for resistance.

Specified value: 6.0 to 20.0 Ω (at approx. 20 °C)

If the specified value was Not obtained: 

-- Replace the Oxygen Sensor After Three Way Catalytic Converter -G130- / Heater For Oxygen Sensor 1 After Catalytic Converter -Z29-

If the specified value was obtained: 

Checking voltage supply 

-- Switch the Ignition On

-- Using a multimeter, check the Oxygen Sensor After Three Way Catalytic Converter -G130- / Heater For Oxygen Sensor 1 After Catalytic Converter -Z29- electrical harness connector terminal 1 to engine ground.

Specified value: Battery voltage.

If the specified value was Not obtained: 

-- Check the wiring for an open, high resistance, short circuit to each other, or Ground.

-- Check the electrical harness connector for damage, corrosion, loose or broken terminals.

-- If necessary, repair the faulty wiring connection.

If the specified value was obtained: 

Checking Ground activation 

If the manufacturers test box is being used, perform the following step. 

-- Install the test box.

If the manufacturers test box is not being used, perform the following step. 

-- Remove the Engine Control Module (ECM) -J623-.

-- Using a multimeter, check the Oxygen Sensor After Three Way Catalytic Converter -G130- / Heater For Oxygen Sensor 1 After Catalytic Converter -Z29- electrical harness connector terminal to the Engine Control Module (ECM) -J623- electrical harness connector terminal for an open circuit according to the chart below.

Oxygen Sensor After Three Way Catalytic Converter -G130- / Heater For Oxygen Sensor 1 After Catalytic Converter -Z29- electrical harness connector terminal: Engine Control Module (ECM) -J623- electrical connector T94 terminal:
2 7

Specified value: 1.5 Ω max.

If the specified value was Not obtained: 

-- Check the wiring for an open or high resistance.

-- Check the electrical harness connector for damage, corrosion, loose or broken terminals.

-- If necessary, repair the faulty wiring connection.

If the specified value was obtained: 

If no malfunction is detected in the wiring and the voltage supply was OK: 

-- Replace the Engine Control Module (ECM) -J623-.

Final procedures 

-- Reinstall the right vehicle floor cover.

After the repair work, the following work steps must be performed in the following sequence: 

  1. Check the DTC memory. Refer to DIAGNOSTIC MODE 03 - READ DTC MEMORY .
  2. If necessary, erase the DTC memory. Refer to DIAGNOSTIC MODE 04 - ERASE DTC MEMORY .
  3. If the DTC memory was erased, generate readiness code. Refer to READINESS CODE .