Multi-Pin Connectors A, B And C On Rear Of CLIMATRONIC Control Module, Pin Assignment
Special tools and workshop equipment required
- Test box V.A.G 1598/42
- Adapter cable V.A.G 1598/47
- Template 1598/47-2
20-Pin Harness Connector, in Wiring Diagram T20c
1 - Sunlight Photo Sensor 2 -G134- or Sunlight Photo Sensor -G107-, signal
2 - High Pressure Sensor -G65-
3 - Sunlight Photo Sensor 2 -G134- or Sunlight Photo Sensor -G107-, signal
4 - Air Quality Sensor -G238-
5 - CAN High
6 - CAN Low
7 - Indirect ventilation door control motor -V213-
8 - Indirect ventilation door control motor -V213-
9 - + 5V for sunlight photo sensor 2 -G134- or sunlight photo sensor -G107-
10 - Heated driver seat adjuster -E94- (optional)
11 - Heated front passenger seat adjuster -E95- (optional)
12 - Terminal 75 (optional)
13 - Outlet temperature sensor -G150-
14 - Right Vent Temperature Sensor -G151-
15 - Indirect ventilation flap motor position sensor -G330-
16 - Terminal 30a/without auxiliary heater terminal 15
17 - Signal ground for sunlight photo sensor -G107-, sunlight photo sensor 2 -G134-, left vent temperature sensor -G150-, right vent temperature sensor -G151- and indirect ventilation flap motor -V213-
18 - A/C Compressor Regulator Valve -N280-
19 - Terminal 31
20 - Terminal 30a/without auxiliary heater terminal 15
16-Pin Harness Connector, in Wiring Diagram T16c
1 - + 5V for motors
2 - Temperature Regulator Door Motor Position Sensor -G220-
3 - Right Temperature Door Potentiometer/Actuator -G221-
4 - Defroster Door Motor Position Sensor -G135-
5 - Front air distribution flap motor position sensor -G642-
7 - Fresh air/recirculating air/back pressure flap motor position sensor -G644-.
8 - Footwell Outlet Temperature Sensor -G261-
9 - Right Footwell Vent Temperature Sensor -G262-
11 - Evaporator vent temperature sensor -G263- or evaporator temperature sensor -G308-
14 - Signal ground (GND) potentiometer
16-Pin Harness Connector, in Wiring Diagram T16d
1 - Left Temperature Door Motor -V158-, cold
2 - Left Temperature Door Motor -V158-, warm
3 - Defroster Door Motor -V107-, closed
4 - Defroster Door Motor -V107-, open
5 - Front air distribution flap motor -V426-, upper body outlet
6 - Front air distribution flap motor -V426-, footwell
9 - Fresh air/recirculating air/back pressure flap motor -V425-, open
10 - Fresh air/recirculating air/back pressure flap motor -V425-, closed
11 - Right Temperature Door Motor -V159-, cold
12 - Right Temperature Door Motor -V159-, warm
15 - Fresh Air Blower Control Module -J126-
16 - Control module for fresh air blower -J126-, signal