Pin Assignment, Climatic Control Unit, Through May 27, 2011
Special tools and workshop equipment required
- Test Box -V.A.G 1598/42-
- Test Adapter -V.A.G 1598/47-
- Template -1598/47-2-
20-pin Harness Connector, in Wiring Diagram T20c
3 - Center Outlet Temperature Sensor -G191-
5 - High Pressure Sensor -G65-
7 - CAN Low
8 - CAN High
12 - Right seat heater (optional)
13 - Seat heating (option)
15 - Terminal 75 seat heater (optional)
16 - A/C Compressor Regulator Valve -N280-
18 - Center outlet temperature sensor -G191- ground
19 - Terminal 30A
20 - Terminal 31
16-pin Harness Connector, in Wiring Diagram T16e
1 - Temperature regulator door motor -V68-, warm
2 - Evaporator temperature sensor -G308- or Evaporator vent temperature sensor -G263-
3 - Air distribution door motor position sensor -G645-
4 - Footwell outlet temperature sensor -G192-
5 - Temperature regulator door motor position sensor -G92-
7 - + 5 V for Temperature regulator door motor position sensor - G92-
8 - Ground for the Front air distribution door motor position sensor -G92-, the Footwell vent temperature sensor -G192- ; the air distribution door motor position sensor -G645- and the evaporator temperature sensor -G308- or evaporator vent temperature sensor -G263-
9 - Recirculation door motor -V113-, open
10 - Recirculation door motor -V113-, close
11 - Temperature regulator door motor -V68-, cold
12 - Air distribution door motor -V428-, open
13 - Air distribution door motor -V428-, closed
5-pin Harness Connector, in Wiring Diagram T5
1 - 3rd Blower Speed
2 - 2nd Blower Speed
3 - 1st Blower Speed
4 - 4th Blower Speed
5 - Terminal X