Home >> Volkswagen >> 2011 >> CC R-Line, 2.0 P, Automatic DCT >> Repair and Diagnosis >> Engine Performance >> Ignition System >> General, Technical Data - Refrigerant R134A Servicing >> 00 General, Technical Data >> Description And Operation >> A/C Service Station >> Servicing Station, Connecting For Measuring And Testing
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Servicing Station, Connecting For Measuring And Testing

NOTE:

The work procedure is always to be performed as described in the operating instructions for the A/C service station ROB 134APF (or subsequent models).

The charging hoses are to be connected as follows to prevent the entry of air or moisture into the refrigerant circuit:

-- Switch off the ignition.

-- Connect service station to power supply.

-- Connect quick-release coupling adapter to charging hoses of service station (handwheels not screwed in/hand shut-off valve not open).

-- Switch on service station and evacuate charging hoses (only necessary if there is air in charging hoses).

-- Switch off service station.

-- Remove sealing caps from service connections or connections with valve (see vehicle-specific refrigerant circuit).

Refer to [For engine(s) BLV, CCTA, CBFA] Removal and Installation .

NOTE:

Connect filler hose with quick-release couplings to refrigerant circuit service connections.

CAUTION:

Never open valves on low or high-pressure side with engine running. Otherwise, the compressor or service station could be destroyed by a short circuit between the high and low-pressure sides of the refrigerant circuit if the A/C system is switched on.

-- Only tighten the handwheel in the quick-release coupling just enough so the service connection is open. Watch the pressure gauge and do not place too much pressure on the valve.

-- Start the engine and perform the planned tests and measurements.

-- Compare values determined to specified measured values. Refer to TEST PREREQUISITES .

-- Loosen the handwheel to close the quick-release coupling before disconnecting it.