Monitor-ID $3D: EVAP Valve Function Check
-- Connect the scan tool.
-- Start the engine and run at idle.
-- Select "Mode 6: Check test the results of components that are not continuously monitored".
Select "Monitor-ID 3D".
-- Select the desired "Test-ID".
-- Check specified values at idle.
| Test-ID | DTC | Component or System | Min. | Max. | Additional Information |
|---|---|---|---|---|---|
| $8C: | P0441 | Purge flow monitor valve open. (2012>) | 0.000 mA | 14.000 mA | Refer to DTC P0441 in the DTC TABLES . |
| $8D: | P0441 | Purge flow monitor valve closed. (2012>) | 0.000 mA | 36.300 mA | Refer to DTC P0441 in the DTC TABLES . |
| $80 | P0441 | Tank vent valve check from % DTEV: Active test Air balance at idle OK, (Normal operation and short test 70). | .300 | 1.999 | Refer to DTC P0441 in the DTC TABLES . |
| $82 | -- | Tank vent valve check from % DTEV: Active test, Oxygen sensor regulator deviating in lean direction (can only test OK), (Normal operation and short test 70). | 0.07 | 10 | -- |
| $82 | Pass only | Tank vent valve check from % DTEV: Active test, Oxygen sensor regulator deviation in rich direction (can only test OK), (Normal operation and short test 70). | -9.994 to 0.080 | -0.080 to 9.994 | -- |
-- If any of components or systems fail to meet the specified values. Refer to DIAGNOSTIC MODE 03 - READ DTC MEMORY to check for stored DTC's or the corresponding diagnostic repair procedure.
-- Switch the ignition OFF.