LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Volkswagen >> 2010 >> Touareg Base >> Repair and Diagnosis >> Engine Performance >> System >> On Board Diagnostic >> 01 On Board Diagnostic >> Diagnosis And Testing >> Leak Detection Pump, Checking
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Leak Detection Pump, Checking

Special tools and workshop equipment required 

Test requirements 

NOTE:

The voltage for the Leak Detection Pump (LDP) --V144-- is supplied via the Motronic Engine Control Module (ECM) Power Supply Relay -J271-.

Test procedure 

-- Perform a preliminary check to verify the customers complaint. Refer to PRELIMINARY CHECK .

Start diagnosis 

-- Remove the left rear wheel housing liner.

-- Disconnect the Leak Detection Pump (LDP) -V144- electrical harness connector -3-.

Fig 1: Checking Electrical Harness Connector For Damage, Corrosion, Lose Or Broken Terminals
GWWA20-10055Courtesy of VOLKSWAGEN GROUP OF AMERICA, INC.

Checking internal resistance 

-- Using a Multimeter --, check the Leak Detection Pump (LDP) -V144- for resistance as follows:

Fig 2: Checking Leak Detection Pump (LDP) V144 For Resistance
GWWA24-0123Courtesy of VOLKSWAGEN GROUP OF AMERICA, INC.
Leak Detection Pump (LDP) -V144- electrical connector terminals Specified value
-1- + -3- 640 to 720 Ω
-2- + -3- 15 to 17 Ω

If the specifications was not obtained:

-- Replace the Leak Detection Pump (LDP) --V144--.

If the specified values are obtained:

Checking voltage supply 

-- Check the Leak Detection Pump (LDP) --V144-- for voltage.

-- Using a Multimeter --, check the Leak Detection Pump (LDP) --V144-- electrical harness connector terminal 3 to Ground (GND) for voltage.

Fig 3: 3-Pin Electrical Harness Connector & Terminals
GWWN24-1648Courtesy of VOLKSWAGEN GROUP OF AMERICA, INC.
Leak Detection Pump (LDP) --V144-- electrical harness connector terminal Measure to
-3- Engine Ground (GND)

-- Operate the starter briefly.

Specified value: battery voltage.

-- Switch the ignition off.

If the specified value was not obtained:

If the manufacturers test box is being used. Perform the following step.

-- Install the test box.

If the manufacturers test box is not being used. Perform the following step.

-- Remove the Motronic Engine Control Module (ECM) -J623-. Refer to ENGINE CONTROL MODULE, REPLACING .

-- Using a Multimeter --, check the Leak Detection Pump (LDP) --V144-- electrical harness connector terminal 3 to the Motronic Engine Control Module (ECM) Power Supply Relay -J271- terminal 2/87 for resistance.

Fig 4: 3-Pin Electrical Harness Connector & Terminals
GWWN24-1648Courtesy of VOLKSWAGEN GROUP OF AMERICA, INC.

Specified value: Wire resistance 1.5 Ω.

If the specification was not obtained:

-- Check the wiring for a short circuit to Battery positive (+) or an open circuit.

-- Check the electrical harness connector for damage, corrosion, loose or broken terminals.

-- If necessary, repair the faulty wiring connection.

If no malfunction is detected in the wiring and if the voltage supply is OK:

Checking output wiring 

-- Using a Multimeter --, check the Leak Detection Pump (LDP) --V144-- electrical connector terminal 1 to Motronic Engine Control Module (ECM) -J623- electrical connector T94 terminal 40 for an open circuit.

-- Using a Multimeter --, check the Leak Detection Pump (LDP) --V144-- electrical connector terminal 2 to Motronic Engine Control Module (ECM) -J623- electrical connector T94 terminal 10 for an open circuit.

Fig 5: 3-Pin Electrical Harness Connector & Terminals
GWWN24-1648Courtesy of VOLKSWAGEN GROUP OF AMERICA, INC.
Leak Detection Pump (LDP) --V144-- electrical connector terminals Motronic Engine Control Module (ECM) -J623- electrical connector T94 terminals or test box socket
-1- 40
-2- 10

Specified value: 1.5 Ω.

If the specification is not obtained:

-- Check the wiring for a short circuit to Battery positive (+) or an open circuit.

-- Check the electrical harness connector for damage, corrosion, loose or broken terminals.

-- If necessary, repair the wiring connection.

-- Erase the DTC memory. Refer to DIAGNOSTIC MODE 04 - ERASE DTC MEMORY .

-- Perform a road test to verify repair.

If the DTC does not return:

Repair complete, Generate readiness code. Refer to READINESS CODE .

-- End diagnosis.

If the DTC does return and no malfunction is detected in the wiring and the voltage supply was OK:

-- Replace the Motronic Engine Control Module (ECM) -J623-. Refer to ENGINE CONTROL MODULE, REPLACING .

-- Assembly is performed in the reverse of the removal.

Final procedures 

After repair work, the following work steps must be performed in the mentioned sequence:

  1. Check the DTC memory. Refer to DIAGNOSTIC MODE 03 - READ DTC MEMORY .
  2. If necessary, erase the DTC memory. Refer to DIAGNOSTIC MODE 04 - ERASE DTC MEMORY .
  3. If the DTC memory was erased, generate readiness code. Refer to READINESS CODE .