IAT In MAF Sensor, Checking: Notes
The Mass Air Flow sensor and the Intake Air Temperature sensor are combined as a unit and are serviced as an assembly.
Use only gold-plated terminals when servicing terminals in the electrical harness connector of the MAF / IAT sensor -G70 / G42-.
Special tools and workshop equipment required
- Multimeter.
- Wiring diagram.
Test procedure
-- Observe safety precautions. Refer to SAFETY PRECAUTIONS
-- Observe Clean Working Conditions. Refer to CLEAN WORKING CONDITIONS
-- Perform a preliminary check to verify the customers complaint. Refer to PRELIMINARY CHECK
Start diagnosis
-- Connect the scan tool.
-- Engine MUST be at room temperature.
-- Switch the ignition ON.
-- Using the scan tool, check the intake air temperature:
| Diagnostic text | Specified value | |||
|---|---|---|---|---|
| Intake Air Temperature (IAT) | actual ambient air temperature | |||
If the specified value was obtained:
-- Fault may be intermittent. Check for proper connection, damaged wiring or loose terminals.
If the specified value was Not obtained:
Checking internal resistance
-- Disconnect the MAF / IAT sensor -G70 / G42- electrical harness connector.
-- Using a multimeter, check the MAF / IAT sensor -G70 / G42- terminals 3 to 4 for resistance.
Use the chart below for the specified values:
Specified values:
| IAT Temperature vs Resistance | ||
| Temp (C) | min. value ohms | max. value ohms |
| - 35 | 28840 | 33978 |
| - 25 | 17680 | 20530 |
| - 15 | 10940 | 12534 |
| - 5 | 6897 | 7804 |
| 0 | 5535 | 6226 |
| 5 | 4443 | 4970 |
| 15 | 2923 | 3235 |
| 25 | 1978 | 2167 |
| 35 | 1369 | 1486 |
| 45 | 965 | 1039 |
| 55 | 692 | 738 |
| 65 | 503 | 533 |
| 75 | 372 | 392 |
If the specified values were Not obtained:
-- Replace the MAF / IAT sensor -G70 / G42- Refer to the Repair Information.
If the specified values are obtained, continue the test according to the following table:
| Indicated reading | Cause | Test |
|---|---|---|
| approx. - 40 °C to -46 °C | Open circuit or short circuit to (B+) | TESTING IF DISPLAY APPROX. - 40° C TO - 46° C |
| approx. 140 °C | Short circuit to Ground | TESTING IF DISPLAY APPROX. 140° C |