Test Step 4 - Liftgate Open Driver Wire Short to Ground
- Disconnect the power liftgate drive unit connector.
- Measure the resistance between ground and the liftgate open driver circuit.
Is the resistance less than 10k ohms?
Yes
- Repair the liftgate open driver circuit for a short to ground.
- Perform the Body Verification Test. Refer to BODY VERIFICATION TEST .
No
- Go to Test Step 5 Test Step 5 - Liftgate Close Driver Wire Short to Ground