Pin Assignment, CLIMATRONIC Control Unit
Special tools and workshop equipment required
- Test Box -V.A.G 1598/42-
- Test Adapter -V.A.G 1598/47-
- Template -1598/47-2-
20-pin Harness Connector -A-, in Wiring Diagram T20c
1 - Sunlight photo sensor 2 -G134- or Sunlight photo sensor - G107-, signal
2 -
3 - Sunlight photo sensor 2 -G134- or Sunlight photo sensor - G107-, signal
5 - High speed CAN Bus
6 - Low speed CAN Bus
9 - + 5V for Sunlight photo sensor 2 -G134- or Sunlight photo sensor -G107-
10 - Heated driver seat adjuster -E94- (optional)
11 - Heated front passenger seat adjuster -E95- (optional)
12 - Terminal 75 (optional)
13 - Left vent temperature sensor -G150- (from January 2004)
14 - Right vent temperature sensor -G151- (from January 2004)
16 - Terminal 30a/ terminal 15
17 - Signal Ground (GND) for Sunlight photo sensor -G107-, Sunlight photo sensor 2 -G134-, Left vent temperature sensor - G150- and Right vent temperature sensor -G151-.
18 - A/C compressor regulator valve -N280-
19 - Terminal 31
20 - Terminal 30a/ terminal 15
16-pin Connector, -B-, In Wiring Diagram T16c9 - + 5V for Sunlight photo sensor 2 -G134- or Sunlight photo sensor -G107-
1 - + 5V for motors
2 - Left temperature door potentiometer/actuator -G220-
3 - Right temperature door potentiometer/actuator -G221-
4 - Defroster door motor position sensor -G135-
5 - Front air distribution door motor position sensor -G642-
6 - Recirculation door motor position sensor -G143- (through December 2003) temperature regulator door motor position sensor -G92- (from January 2004)
7 - Back pressure door motor position sensor -G113-
8 - Left footwell vent temperature sensor -G261-
9 - Right footwell vent temperature sensor -G262-
10 - Fresh air intake duct temperature sensor -G89- (through September 2005)
11 - Evaporator temperature sensor -G308- or Evaporator vent temperature sensor -G263-
14 - Signal Ground (GND) potentiometer
15 - Left vent temperature sensor -G150- (through December 2003)
16 - Right vent temperature sensor -G151- (through December 2003)
16-pin Connector, -C-, In Wiring Diagram T16d
1 - Left temperature door motor -V158-, cold
2 - Left temperature door motor -V158-, warm
3 - Defroster door motor -V107-, closed
4 - Defroster door motor -V107-, open
5 - Front air distribution door motor -V426-, upper body outlet
6 - Front air distribution door motor -V426-, footwell
7 - Fresh/recirculation air door motor -V154- air recirculation activation (through December 2003) air recirculation door motor - V113- (from January 2004); motor function deleted (from June 2007) by the fresh air/recirculating air/back pressure door motor -V425- and mount.
8 - Fresh/recirculation air door motor -V154- fresh air activation (through December 2003) air recirculation door motor -V113- (from January 2004)
9 - Airflow door motor -V71-, open (through May 2007)
10 - Airflow door motor -V71-, closed (until May 2007)
11 - Right temperature door motor -V159-, cold-
12 - Right temperature door motor -V159-, warm
15 - Fresh air blower control module -J126-
16 - Control module for fresh air blower -J126-, signal