Test Step 5 - Liftgate Full Open Switch Sense Circuit Short to Ground
- Connect the power liftgate module C2 harness connector.
- Turn the ignition ON.
- Measure the voltage between liftgate full open switch sense circuit and the sensor ground in the power driver unit connector.
- While measuring the voltage, wiggle the power liftgate module to check for an intermittent short.
Is the voltage constantly above 4.6 volts?
Yes
- Replace the power liftgate drive unit. Refer to POWER LIFTGATE DRIVE UNIT .
- Perform the Body Verification Test. Refer to BODY VERIFICATION TEST .
No
- Go to Test Step 6 Test Step 6 - Liftgate Full Open Switch Sense Circuit Short to Ground