Test Step 5 - Liftgate Close Driver Wire Short to Ground
- Measure the resistance between ground and the liftgate close driver circuit in the power liftgate module C1 connector.
Is the resistance less than 10k ohms?
No
- Replace the power liftgate drive unit. POWER LIFTGATE DRIVE UNIT .
- Perform the Body Verification Test. Refer to BODY VERIFICATION TEST .
Yes
- Repair the liftgate close driver circuit for a short to ground.
- Perform the Body Verification Test. Refer to BODY VERIFICATION TEST .