P129C - Inverter Control Circuit High: Notes
For a complete wiring diagram, refer to appropriate SYSTEM WIRING DIAGRAM.
- >>When Monitored:<< With the ignition on. Battery voltage greater than 10 volts.
- >>Set Condition:<< An open or shorted high condition has been detected in the Inverter Enable Switch Signal circuit by the Totally Integrated Power Module (TIPM).
| Possible Causes |
|---|
| (P805) INVERTER ENABLE SWITCH SIGNAL CIRCUIT OPEN |
| (P805) INVERTER ENABLE SWITCH SIGNAL CIRCUIT SHORTED TO VOLTAGE |
| INVERTER MODULE |
| TOTALLY INTEGRATED POWER MODULE (TIPM) |