Diagnostic Mode 01 - Read Current System Data
Special tools and workshop equipment required
- Scan Tool
Function
Diagnostic Mode 01 makes it possible to access current emissions-related measured values and diagnostic data. The original measured values (no replacement values), input and output data and system status information are displayed using Diagnostic Mode 1.
Prerequisite
- Coolant temperature must be at least 80° C → PID 5, Coolant temperature.
Procedure
-- Connect diagnostic tester.
-- Depending on the desired operating condition: switch on ignition
or start engine and let run at idle.
-- Under address word 33, select "Diagnostic mode 1: Checking measured values."
-- Select the desired measured values "PID XX".
The specified values for the respective measuring values can be found at the respective component- and Function Tests.
The following list only serves as an overview.
The measuring values are sorted according to the PID (parameter identifications).
Bank 1 = Cylinder bank 1, in direction of travel, right.
Bank 2 = Cylinder bank 2, in direction of travel, left.
| PID | Diagnostic mode | Module number 10 (bank 1) and 11 (bank 2) Engine electronics | Module number 1A Transmission Electronics | ||
|---|---|---|---|---|---|
| 01: | Monitoring status since erasing DTC memory | X | X | ||
| 04: | Calculated load condition value | X | --- | ||
| 05: | Coolant temperature | X | X | ||
| 11: | Intake manifold pressure | X | --- | ||
| 12: | Engine rotations per minute | X | X | ||
| PID | Diagnostic mode | Module number 10 (bank 1) and 11 (bank 2) Engine electronics | Module number 1A Transmission Electronics | ||
|---|---|---|---|---|---|
| 13: | Vehicle speed | X | X | ||
| 15: | Intake Air Temperature (IAT) | X | --- | ||
| 16: | Air flow quantity at Mass Air Flow (MAF) sensor | X | --- | ||
| 17: | Pedal value sensor | X | X | ||
| 28: | OBD Prerequisite for which this vehicle is designed | X | X | ||
| 36: | Oxygen sensor value/sensor voltage bank 1 sensor 1 | X | --- | ||
| 40: | Oxygen sensor value/sensor voltage bank 2 sensor 1 | X | --- | ||
| 79: | Scaling factor of oxygen sensor value | X | --- | ||
-- End diagnosis and switch ignition off.