Procedures






B+ Wire Connection to Generator


When disconnecting and connecting the Battery, the procedure must be followed as described in the repair information. Refer to=> [ Battery, Disconnecting and Connecting ] Battery, Disconnecting and Connecting.


If the B+ wire is not tightened to the specification, the following may occur:

The battery will not be completely charge.

The complete electrical/electronics systems may fail (disabled vehicle).

Fire hazard due to arcing.

Damage to electronic components and control modules caused by excessive voltage.

Torque specification of B+ wire nut - arrow - is 20 Nm.