Sae U0XXX Diagnostic Trouble Codes

Control module and output signals

DTC Error Message Diagnostic Procedure Malfunction Criteria and Threshold Value Secondary Parameters with Enable Conditions Monitoring Time Length Frequency of checks, MIL Illumination
U0001 High Speed CAN Communication Bus -- Refer to CAN-BUS TERMINAL RESISTANCE, CHECKING . CAN message, No feedback Battery voltage, 9.49-16.5 V 0.5 Seconds
  • 2 DCY
U0100 Lost Communication with ECM/PCM A -- Refer to CAN-BUS TERMINAL RESISTANCE, CHECKING .
  • Failure of all CAN engine messages, Time out more than 490 ms
  • Failure of all CAN engine messages but not all CAN messages, Time out more than 1010 ms
  • No bus off error
  • No error failure of all CAN messages
  • No error failure of all CAN engine messages
  • Terminal 15 Voltage, > 9 V for more than 500 ms
  • > 500 ms after reset
1 Second  
U0101 Lost Communication with TCM -- Refer to DSG MECHATRONIC CAN-BUS TERMINAL RESISTANCE, CHECKING .
  • Checksum check Failed Message counter check failed
  • Time out check No message received by ECM
- 0.5 Seconds
  • 2 DCY
U0302 Software Incompatibility with Transmission Control Module -- Replace the Direct Shift Gearbox (DSG) Mechatronic -J743-. Refer to DSG Transmission Mechatronic -J743-, TRANSMISSION INSTALLED . AT vehicle ECM coded as MT vehicle - 800 ms -
U0404 Invalid Data Received From Gear Shift Control Module -- Refer to SELECTOR LEVER CAN-BUS TERMINAL RESISTANCE, CHECKING . If the value of message counter is permanent, constant, or change exceeds a threshold, increment an event counter maximum change of message counter > 5 no failure of selector lever CAN messages terminal 15 voltage > 4 V for more than 500 ms 50 ms
  • Continuous
  • 2 DCY