Control Module, Removing From Hydraulic Unit
-- Set hydraulic unit with control module upward onto a clean, level surface.
-- Remove inner Torx® bolts -arrows-.
-- Pull control module off from hydraulic unit -arrow- without angling.
-- Carefully pull off all sealing rings from valve domes of hydraulic unit.
WARNING:
- On a disconnected control module, circuit board is laid open.
- No moisture or particles of dirt must penetrate in interior of control module.
- The hydraulic pump must not be separated from the hydraulic unit.
- Avoid build-up of static electricity!
-- Cover control module magnetic coils with a lint free cloth.
After separating the control module and hydraulic unit, use transport protection for valve body.