A/C Control Module Connector End View (J301, T16j)
| Cavity | Function |
|---|---|
| 1 | Temperature regulator door motor, hot |
| 2 | Signal, Evaporator vent temperature sensor |
| 3 | Signal, Air distribution door motor position sensor (RHD) |
| 4 | Signal, Footwell vent temperature sensor |
| 5 | Signal, temperature door potentiometer/actuator |
| 6 | -- |
| 7 | 5 Volt, output |
| 8 | Ground, sensor |
| 9 | Recirculation door motor, open |
| 10 | Recirculation door motor, close |
| 11 | Temperature regulator door motor, cold |
| 12 | Air distribution door motor, mode 1 |
| 13 | Air distribution door motor, mode 2 |
| 14 | -- |
| 15 | -- |
| 16 | -- |