Diagnostic Mode 06 - Read Test Results For Specific Diagnostic Functions: Notes
Diagnostic Mode 06 makes it possible to retrieve test results for special components and systems which are continuously or not continuously monitored. If the diagnosis of a system is complete, the diagnostic result and the corresponding thresholds are saved and displayed in mode 06. This data remains saved (even with the ignition off) until either new diagnostic results become available or the DTC memory is erased.
The min & max values for each individual test in Mode 06 represent the min & max operating values for a properly operating system. This data is provided to the individual aftermarket scan tool companies for development of their scan tool. Depending on the scan tool being used, the min & max values shown may vary, or be rounded up or down to the nearest decimal point depending on the aftermarket scan tool company's development process. e.g.:
| Minimum Value | |
|---|---|
| GST Manual documentation | 0.3499 |
| Aftermarket Scan Tool display | 0.35 |
Depending on the scan tool and protocol used, the information displayed in Diagnostic Mode 06 may be referred to by different names such as Test-ID (TID), Hex-ID, Component-ID (CID), On-Board Diagnostic Monitor Identifier (OBDMID), or contain no name at all and may be referenced by only a number.
| Engine Code BRM Test-ID (Hex-ID) | Component or System |
|---|---|
| TID 01 ($01):TID 01 ($01): HEATED OXYGEN SENSOR | Heated Oxygen Sensor |
| TID 09 ($09): TID 09 ($09): ENGINE COOLANT TEMPERATURE SENSOR . | Engine Coolant Temperature Sensor |
| TID 11 ($11): TID 11 ($11) FUEL TEMPERATURE SENSOR . | Fuel Temperature Sensor |
| TID 12 ($12): TID 12 ($12): CHARGE AIR PRESSURE SENSOR . | Charge Air Pressure Sensor |
| TID 31 ($31):TID 31 ($31): EXHAUST GAS RECIRCULATION (EGR) | Exhaust Gas Recirculation (EGR) |