Combination Valve, Checking
Special tools and workshop equipment required
- Hand Vacuum Pump VAG 1390
Test requirements
- No leaks in vacuum lines or hose connections.
- Vacuum hoses not clogged or kinked
- Pressure and intake hose for Secondary Air Injection (AIR) Pump Motor not clogged or kinked.
- Ignition switched off.
Test sequence
-- Disconnect vacuum hose from Secondary Air Injection (AIR) Solenoid Valve -N112- at combination valve (arrow).
-- Connect hand vacuum pump (VAG 1390) to vacuum connection of combination valve (arrow).
Do not use pressurized air for the following test!
-- Disconnect pressure hose (arrow) from Secondary Air Injection (AIR) Pump Motor -V101- at pressure line.
-- Attach assisting hose onto pressure line and blow into with light pressure.
Combination valve must close.
-- Operate vacuum pump.
Combination valve must open.
If the combination valve does not open or it is constantly open:
-- Replace combination valve.
Final Procedures
After the repair work, the following work steps must be performed in the following sequence:
- Check the DTC memory. Refer to DIAGNOSTIC MODE 03 - READ DTC MEMORY .
- If necessary, erase the DTC memory. Refer to DIAGNOSTIC MODE 04 - ERASE DTC MEMORY .
- If the DTC memory was erased, generate readiness code. Refer to READINESS CODE .