Home >> Volkswagen >> 2004 >> Jetta GLI, 1.8 E >> Repair and Diagnosis >> Engine Performance >> Ignition System >> 1.8L - Fuel Injection Ignition, Engine Code(S): AWW, AWP (A4 Platform) >> 28 Ignition/Glow plug system >> Ignition system, servicing >> Misfiring recognition, checking >> Test sequence >> Notes
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Test sequence: Notes

Indicated on display:

Rapid data transfer HELP
Select function XX

Indicated on display:

Read measured value block
Input display group number XXX

Indicated on display: (1 to 4 = Display zones)

Read measured value block 14 →
1 2 3 4
  Display zones
  1 2 3 4
Display group 14: Ignition, misfire recognition (while driving)
Display xxxx rpm xxx.x% xxx Activated Blocked
Indicated Engine speed (in 40 steps) Engine load Exhaust damaging misfires (Total) Misfire recognition status
Specification 640 to 6500 rpm > 10.0% 0 activated
  --- --- If the specification is not obtained: Evaluating display group 14, display zone 3 - total number of exhaust damaging misfires  , Evaluating display group 14

If specifications are obtained:

If specifications are not attained:

Indicated on display: (1 to 4 = Display zones)

Read measured value block 15 →
1 2 3 4
  Display zones
  1 2 3 4
Display group 15: Ignition, misfire recognition (while driving)
Display xxx xxx xxx Activated Blocked
Indicated Exhaust damaging misfires Cyl. 1 Exhaust damaging misfires Cyl. 2 Exhaust damaging misfires Cyl. 3 Misfire recognition status
Specification 0 0 0 activated
  If the specification is not obtained Evaluating display group 14, display zone 3 - Total number of misfires   , Evaluating display groups 15 and16

If specifications are obtained:

Indicated on display: (1 and 4 = Display zones)

Read measured value block 16 →
1 4
  Display zones
  1 2 3 4
Display group 16: Ignition, misfire recognition (while driving)
Display xxx     activated deactivated
Indication Emissions damaging misfire cyl. 4     Status of misfire recognition
Specification 0     activated
  If the specification is not obtained Evaluating display group 14, display zone 3 - Total number of misfires   , Evaluating display groups 15 and16