Read Measuring Value Block
NOTE:
The measured values in the functions Read Measuring Value Block and basic setting are described during the individual component test. This table shows an overview. See Fig 2
. The measured value block is divided into 16 display group numbers. The assignment of the individual display zones can be taken from display group overview. See Fig 2
.
- Connect scan tool. See Figure .
- Press buttons "0" and "8" (08 indicates the "Read Measuring Value Block" function.
- Confirm entry with the "Q" button.NOTE: The display group number 001 is an example, to illustrate the sequence.
- Press buttons "0," "0," and "1" for "Display group number 1" and confirm entry with "Q" button.
- Indicated on the display will be the display zones for display group 1 (1-4).NOTE: To change to another display group, see Fig 1 .