LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Volkswagen >> 2003 >> EuroVan Base >> Repair and Diagnosis >> External Pages >> Different car >> Section 4 (Automatic A/C-Heater Systems) >> Symptom Tests >> Fresh Air Mode Cannot Be Switched Off, RECIRCULATION Function Inoperative
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Fresh Air Mode Cannot Be Switched Off, RECIRCULATION Function Inoperative

WARNING: This page is about a different car, the 2001 Volkswagen EuroVan, 2000 Volkswagen EuroVan, 1999 Volkswagen EuroVan, and 1997 Volkswagen EuroVan. However, it is still accessible from the selected car via links, so may be relevant.

Test fuses No. S6 (30-amp), S16 (15-amp) and SB14 (30-amp). If fuses are okay, check DTC memory with scan tool and verify no DTCs exist. Start engine and run at full vacuum. Select RECIRCULATING AIRFLOW at A/C control head. Check for blocked fresh air intake. If fresh air intake is blocked, check for open or short circuits in wiring to vacuum valve rail. See WIRING DIAGRAMS  . Check for closed fresh/recirculating vacuum air flap. If fresh/recirculating vacuum air flap is not functioning properly, check vacuum hoses. See Figure .