Diagnostic mode 5: Check output of oxygen sensor signals

Function 

The static values of the oxygen sensors are indicated via this diagnostic mode.

The values of the individual oxygen sensor signal outputs must reach the specified value or must be within the min.- and max.- limits.

Requirements 

Work sequence 

Test-ID:  Evaluation of output of oxygen sensor signals 
01 Bank 1 and 2, sensor 2: Rich to lean sensor barrier voltage Refer to Evaluation test-ID 01 Bank 1 and 2, sensor 2: Rich to lean sensor barrier voltage 
02 Bank 1 and 2, sensor 2: Lean to rich sensor barrier voltage Refer to Evaluation test-ID 02 Bank 1 and 2, sensor 2: Lean to rich sensor barrier voltage 
07 Bank 1 and 2, sensor 2: Minimum voltage at sensor for test cycle Refer to Evaluation test-ID 07 Bank 1 and 2, sensor 2: Minimum voltage at sensor for test cycle 
08 Bank 1 and 2, sensor 2: Maximum voltage at sensor for test cycle Refer to Evaluation test-ID 08 Bank 1 and 2, sensor 2: Maximum voltage at sensor for test cycle 
129 Bank 1 and 2, sensor 1: Actual value of oxygen sensor voltage Refer to Evaluation test-ID 129 Bank 1 and 2, sensor 1: Actual value of oxygen sensor voltage 
130 Bank 1 and 2, sensor 1: Control barrier voltage Refer to Evaluation test-ID 130 Bank 1 and 2, sensor 1: Control barrier voltage 
131 Bank 1 and 2, sensor 1: Dynamic value Refer to Evaluation test-ID 131 Bank 1 and 2, sensor 1: Dynamic value 
132 Bank 1 and 2, sensor 1: Oxygen sensor shift via oxygen sensor control behind Three Way Catalytic Converter (TWC) (bank 1 and 2, sensor 2) Refer to Evaluation test-ID 132 Bank 1 and 2, sensor 1: Oxygen sensor shift via oxygen sensor control behind Three Way Catalytic Converter (TWC) (bank 1 and 2, sensor 2) 
NOTE:
  • Bank 1 = Cylinder bank 1, in direction of travel, right
  • Bank 2 = Cylinder bank 2, in direction of travel, left
  • When selecting the diagnostic mode, the entry is always performed in "Bank 1 sensor 1".
  • If either the VAG1551/1552 Scan Tool (ST) or VAS5051/5052 Vehicle Diagnostic, Testing and Information System is used for checking the output of oxygen sensor signals, the respective oxygen sensor can be selected by pressing buttons 1, 2, 5 and 6:
Evaluation test-ID 01 Bank 1 and 2, sensor 2: Rich to lean sensor barrier voltage

Oxygen sensor  Specified value: 
  • Bank 1 sensor 2
Fixed value: 0.631 V
  • Bank 2 sensor 2
Fixed value: 0.631 V

If specified value is not obtained:

Evaluation test-ID 02 Bank 1 and 2, sensor 2: Lean to rich sensor barrier voltage

Oxygen sensor  Specified value: 
  • Bank 1 sensor 2
Fixed value: 0.631 V
  • Bank 2 sensor 2
Fixed value: 0.631 V

If specified value is not obtained:

Evaluation test-ID 07 Bank 1 and 2, sensor 2: Minimum voltage at sensor for test cycle

Oxygen sensor  Specified value: 
  min.  max. 
  • Bank 1 sensor 2
0.031 V 0.402 V
  • Bank 2 sensor 2
0.031 V 0.402 V

If the specified value is exceeded:

Evaluation test-ID 08 Bank 1 and 2, sensor 2: Maximum voltage at sensor for test cycle

Oxygen sensor  Specified value: 
  min.  max. 
  • Bank 1 sensor 2
0.501 V 1.080 V
  • Bank 2 sensor 2
0.501 V 1.080 V

If the specified value is not reached:

If the specified value is exceeded:

Evaluation test-ID 129 Bank 1 and 2, sensor 1: Actual value of oxygen sensor voltage

Oxygen sensor  Specified value: 
  min.  max. 
  • Bank 1 sensor 1
0.992 V 1.078 V
  • Bank 2 sensor 1
0.992 V 1.078 V

If specified values are not obtained:

Evaluation test-ID 130 Bank 1 and 2, sensor 1: Control barrier voltage

Oxygen sensor  Specified value: 
  min.  max. 
  • Bank 1 sensor 1
0.992 V 1.078 V
  • Bank 2 sensor 1
0.992 V 1.078 V

If specified values are not obtained:

Evaluation test-ID 131 Bank 1 and 2, sensor 1: Dynamic value

Oxygen sensor  Specified value: 
  min.  max. 
  • Bank 1 sensor 1
0.996 4.000
  • Bank 2 sensor 1
0.996 4.000

If specified values are not obtained:

Evaluation test-ID 132 Bank 1 and 2, sensor 1: Oxygen sensor shift via oxygen sensor control behind Three Way Catalytic Converter (TWC) (bank 1 and 2, sensor 2)

Oxygen sensor  Specified value: 
  min.  max. 
  • Bank 1 sensor 1
-0.03 0.03
  • Bank 2 sensor 1
-0.03 0.03

If specified values are not obtained: