EVAP system, checking using KLI 9210 tester: Introduction
The Evaporative Emissions Tester KLI9210DLX tester allows testing using nitrogen to pressurize the EVAP system and a smoke generator or ultrasonic tester to locate the source of EVAP system concerns.
This procedure is intended as a general guide for the use of the EVAP tester. EVAP systems vary between models.
Special tools, testers and auxiliary items required
- diagnostic tester VAS 5051 or diagnostic tester VAS 5052
- Evaporative Emissions Tester KLI9210DLX (set to 14 in. H 2 O)
- Light source (for viewing smoke)
- Special tool 3094 or equivalent
Using the Evaporative Emissions Tester KLI9210DLX → Tester operating instructions