Cooling System Specifications: Notes
BELT ADJUSTMENT SPECIFICATIONS
| Application |
Specification |
| A/C Compressor |
|
| Generator |
|
| Power Steering |
|
COOLING SYSTEM SPECIFICATIONS
| Application |
Specification |
| Volume |
9.7 Qts. (9.2L) |
| Cooling Fan Thermal Switch |
| First Stage |
| On |
183-192°F (84-89°C) |
| Off |
168-181°F (76-83°C) |
| Second Stage |
| On |
194-203°F (90-95°C) |
| Off |
180-192°F (82-89°C) |
| Thermostat |
| Starts To Open |
176°F (80°C) |
| Fully Open |
221°F (105°C) |
| Opening Stroke |
.28" (7mm) |
| Reservoir Cap Opening Pressure |
17-22 psi |
Courtesy of VOLKSWAGEN UNITED STATES, INC.