SAE P0xxxDTCs: Overview
For additional Monitor Strategy information. Refer to Bosch Motronic ME 7.1.1 OBD System Strategy document.
Fuel, air mixture, and additional emissions regulations
| DTC | Error Message | Diagnostic Procedure | Malfunction Criteria and Threshold Value | Secondary Parameters with Enable Conditions | Monitoring Time Length | Frequency of checks, MIL Illumination |
| P0010 | Intake (A) Camshaft Position Actuator Circuit / Open (Bank 1) |
|
|
Valve On
|
0.5 Seconds |
|
| P0011 | Intake (A) Camshaft Position Timing - Over-Advanced (Bank 1) |
|
Adjustment angle >12 ° |
|
20 Seconds + 30 Crankshaft Turns |
|
| P0012 | Intake (A) Camshaft Position Timing Over-Retarded (Bank 1) |
|
Adjustment early Crank angle 9 ° |
|
20 Seconds + 30 Crankshaft Turns |
|
| P0021 | "A" Camshaft Position - Timing Over-Advanced or System Performance (Bank 2) |
|
Adjustment angle >12 ° |
|
20 Seconds + 30 Crankshaft Turns |
|
| P0022 | Intake (A) Camshaft Position Timing Over-Retarded (Bank 2) |
|
Adjustment early Crank angle 9 ° |
|
20 Seconds + 30 Crankshaft Turns |
|
| P0030 | HO2S Heater Control Circuit (Bank 1, Sensor 1) |
|
Open circuit, 2.34-3.59 V |
|
5 Seconds |
|
| P0031 | HO2S Heater Control Circuit Low (Bank 1, Sensor 1) |
|
Short to ground, 2.34 V |
|
5 Seconds |
|
| P0032 | HO2S Heater Control Circuit High (Bank 1, Sensor 1) |
|
Short to battery + >3.59 V |
|
5 Seconds |
|
| P0036 | HO2S Heater Control Circuit (Bank 1, Sensor 2) |
|
Heater voltage, 4.5-5.5 V |
|
0.5 Seconds |
|
| P0037 | HO2S Heater Control Circuit Low (Bank 1, Sensor 2) |
|
Heater voltage, 3 V |
|
0.5 Seconds |
|
| P0038 | HO2S Heater Control Circuit High (Bank 1, Sensor 2) |
|
Heater current, 2.75.5 A |
|
0.5 Seconds |
|
| P0050 | HO2S Heater Control Circuit Bank 2 Sensor 1 |
|
Heater voltage 2.34-3.59 V |
|
5 Seconds |
|
| P0051 | HO2S Heater Control Circuit Low Bank 2 Sensor 1 |
|
Heater voltage 2.34 V |
|
5 Seconds |
|
| P0052 | HO2S Heater Control Circuit High Bank 2 Sensor 1 |
|
Heater voltage >3.59 V |
|
5 Seconds |
|
| P0056 | HO2S Heater Control Circuit Bank 2 Sensor 2 |
|
Heater voltage, 4.5-5.5 V |
|
0.5 Seconds |
|
| P0057 | HO2S Heater Control Circuit Low Bank 2 Sensor 2 |
|
Heater voltage, 3 V |
|
0.5 Seconds |
|
| P0058 | HO2S Heater Control Circuit High Bank 2 Sensor 2 |
|
Heater current, 2.75.5 A |
|
0.5 Seconds |
|