Adapter Cable, Installing
Special tools and workshop equipment required
- Wiring Harness Repair Set VAS 1978/A VAS 1978 B
Applies to vehicles between July 4, 2005 and July 13, 2007.
If the generator -C- has to be replaced on these vehicles, then it is necessary to install an adapter cable between the blue connector/contact 16 on the instrument cluster and the brown/black wire, diode number 1Y0.970.082. The adapter wiring set contains a semiconductor diode.
Adapter wiring set:
Adapter wiring set number: 1Y0.970.082.
Perform the following work:
-- Remove the instrument cluster. Refer to INSTRUMENT CLUSTER .
-- Remove the connector housing -1- on the blue connector (T32a) -7-.
-- Remove approximately 105 mm of insulation from the blue connector (T32a) on the wiring harness.
-- Remove the brown/black wire -6- on contact 16 approximately 65 mm from the contact housing -7-.
-- Remove 5 mm (0.2 inches) of insulation on the ends of the wires using the wire stripper VAS 1978/3 in the VAS 1978 B.
-- Make the crimp connections between the wire ends -2-, -6- and the adapter cable -4-.
- Brown wire, adapter cable -5- with the brown/black wire -6- on the contact housing -7-
- Brown/black wire, adapter cable -3- with the brown/black wire, wiring harness -2-
-- Use the crimp pliers (basic tool) VAS 1978/1-2 and exchangeable head, 0.35 mm2 - 2.5 mm2 VAS 1978/1-1.
-- Crimp the connector with the VAS 1978/1-2.
After crimping, crimp connections must be heat-shrunk using hot air blower VAS 1978/14A to prevent moisture penetration.
-- Attach the shrink element for hot air blower VAS 1978/15A on the VAS 1978/14A and warm the crimp connector starting in the center and working outward until it is completely sealed and adhesive starts to run out.
-- Assemble the contact housing -7- and the connector housing -1-.
-- Wrap the wiring harness for the blue connector -1- with tape -3- until the wiring harness -4- is completely wrapped.
-- Secure the wiring harness on the blue connector -1- using a cable tie -2-.
-- Install the instrument cluster.
-- Switch on ignition.
-- Operate the remote rear lid release switch -E188-.
The rear lid unlocked indicator lamp -K116- inside the instrument cluster must turn on. Refer to INSTRUMENT CLUSTER INDICATOR LAMPS .
If the rear lid unlocked indicator lamp does not turn on:
-- Check the crimp connections on the adapter wiring set and check for the correct diode polarity.
- Brown cable, adapter wiring set to the brown/black cable, blue connector (PIN 16).
- Brown / black cable, adapter wiring set to the brown/black cable, wiring harness.