Display group 1 -basic functions-
| Display group 1 -basic functions- | ||||||
|
||||||
| Read Measuring Value Block 1 | → | ← Indicated on display: | ||||
| xxxx/min | xx.x ° C | x.x % | xxxxxxxx | |||
| 1 | 2 | 3 | 4 | ← Display fields | Specified value | Evaluation |
| Adjustment conditions for basic setting | 1x111111 | Refer to Explanation of 8 digit numeric block | ||||
| Oxygen sensor regulation before catalytic converter | -10.0 to 10.0% | Refer to Evaluation display group 33, display field 1 - oxygen sensor control before catalytic converter | ||||
| Coolant temperature | 80 to 110 ° C | Refer to Evaluation display group 4, display field 3 - coolant temperature | ||||
| Engine speed (idle speed) Manual transmission Automatic transmission |
700 to 820 RPM 640 to 760 RPM |
Refer to Evaluation display group 1, display field 1 - engine speed (idle speed) | ||||