WARNING: This page does not describe the selected car, but rather 8 other vehicles, including the 2010 Volkswagen New Beetle, 2009 Volkswagen New Beetle, 2008 Volkswagen New Beetle, 2007 Volkswagen New Beetle, and 2006 Volkswagen New Beetle. However, it is still accessible from the selected car via links, so may be relevant.

Special tools and workshop equipment required 

The USB connection is not capable of On Board Diagnostics (OBD).

The voltage supply can be checked at the connector.

Test Conditions 

Procedure 

-- Remove the USB connection baseplate. Refer to USB CONNECTION BASEPLATE -R193- .

-- Disconnect the connector under the USB connection baseplate.

-- Switch on the radio.

-- Measure the voltage between contacts 3 and 6 as well as between contacts 3 and 8 on the wiring harness connector V.A.G 1526C and the cables from the V.A.G 1594C.

Specified value: approximately 12 V

-- Switch radio off.

Voltage values not OK:

-- Check the wire connections between the radio and the USB connection baseplate according to the wiring diagram. Refer to the appropriate SYSTEM WIRING DIAGRAMS information.

Voltage values OK: