LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Volkswagen >> 2000 >> Golf (1J1) L4-2.0L (AEG) >> Repair and Diagnosis >> Powertrain Management >> PROM - Programmable Read Only Memory >> Technical Service Bulletins >> Recalls >> Recall - Oxygen Sensor Replacement/ECM Software Update >> Sections A - F >> Section B
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Section B

SECTION B - Front Oxygen Sensor Replacement





- Disconnect wire harness connector from oxygen sensor
- Use special tool 3337 to remove front oxygen sensor -1- from exhaust manifold

NOTE: Coat threads of new oxygen sensor, 06A 906 262 Q, using anti-seize compound not containing silicon and marked safe for oxygen sensors . Do not allow compound to enter slots on sensor body

- Install new oxygen sensor (06A 906 262 Q) and tighten to 50 Nm (37 ft. lbs.)
- Reconnect oxygen sensor to wire harness