Home >> Volkswagen >> 2000 >> Golf (1J1) L4-2.0L (AEG) >> Repair and Diagnosis >> Powertrain Management >> Computers and Control Systems >> Testing and Inspection >> Scan Tool Testing and Procedures >> With Manufacturer's Scan Tool >> Read Measuring Value Blocks (Function 08) >> Reading Measuring Value Blocks
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Reading Measuring Value Blocks



Read Measuring Value Block, initiating

Special tools and equipment
V.A.G1551 Scan Tool (ST) or VAG1552 mobile scan tool with VAG1551/3 adapter cable

Requirements
- Turn off all electrical consumers (e.g. lights and rear window defroster).
- Turn off air conditioner, if equipped.
- Automatic transmission selector lever in P (Park) or N (Neutral) position
- No malfunctions stored in DTC memory.
Reading Diagnostic Trouble Codes
Clearing Diagnostic Trouble Codes

- Coolant temperature at least 85°C see display group 004, display field 3

Test procedure
- Connect V.A.G1551 Scan Tool (ST). [1][2]Reading and Clearing Diagnostic Trouble Codes
- Press buttons -0- and -1- to insert "Engine Electronics" address word 01. When doing this engine must be running at idle.

Indicated on display

Rapid data transfer HELP
Select function XX


- Press buttons -0- and -8- to select "Read Measuring Value Block" function 08.

Indicated on display

Read Measuring Value Block
Input display group number XXX


- Select required display group number.

NOTE: The display group number 0 is used as an example to illustrate the sequence.

- Press buttons -0-, -0- and -0- to input display group number 00 (000) and press -Q- button to confirm input.

Indicated on display (1-10 = display fields)

Read Measuring Value Block 0 ->
1 2 3 4 5 8 7 8 9 10


NOTE: To change to another display group proceed as follows:






- If specifications in all display fields are obtained, press -> button.
- If one of the specifications is not obtained Evaluating Measuring Value Blocks

Additional measures see repair procedures.

Indicated on display

Rapid data transfer HELP
Select function XX


- Press buttons -0- and -6- to select "End output" function 06 and press -Q- button to confirm input.
- Turn off ignition.