Display Field No. 3
Position of footwell/defrost flap when selected by defrost button should read 90-100 percent on display Position of footwell/defrost flap when selected by front passenger footwell button should read 0-10 percent. If display is not as specified, check wiring and connectors from CCM to footwell/defrost flap motor position sensor. If wiring is okay, replace footwell/defroster flap motor.