Cooling System Specifications
WARNING: This page is about a different variant/trim than selected.
BELT ADJUSTMENT SPECIFICATIONS
| Application |
Specification |
| A/C Compressor |
|
| Generator |
|
| Power Steering |
| New |
62 INCH Lbs. (7 N.m) |
| Used |
36 INCH Lbs. (4 N.m) |
COOLING SYSTEM SPECIFICATIONS
| Application |
Specification |
| Volume |
6.9 Qts. (6.5L) |
| Cooling Fan Thermal Switch |
| First Stage |
| On |
198-207°F (92-97°C) |
| Off |
183-196°F (84-91°C) |
| Second Stage |
| On |
210-221°F (99-105°C) |
| Off |
196-208°F (91-98°C) |
| Third Stage |
| On |
230-239°F (110-115°C) |
| Off |
221-230°F (105-110°C) |
| Thermostat |
| Starts To Open |
185°F (85°C) |
| Fully Open |
221°F (105°C) |
| Opening Stroke |
.28" (7mm) |
| Reservoir Cap Opening Pressure |
19-22 psi |