Metering Rod
- Ensure accelerator pump stroke is adjusted correctly, and remove air horn from carburetor. Remove metering rod plug, and position a dial indicator with indicator pin resting on metering rod adjusting screw.
- Ensure throttle is fully closed. Preload and zero dial indicator. Using a paper clip, push metering rod adjusting screw downward until metering rod bottoms.