Automatic Choke
- Automatic choke is operated by manifold vacuum and an electrical heating element with a heat sink. Continuous voltage is applied when ignition switch is in "ON" position.
- If battery voltage is indicated at choke electrical connector and element fails to warm after one minute, check for continuity between choke and carburetor body. Choke element should indicate continuity.
- Adjust by locating choke housing notch and index retainer to left of fuel inlet fitting.