Accelerator Pump
- Remove carburetor air horn. Remove plug from air horn. Remove float, needle, lifting link and metering rod. Reinstall carburetor air horn.
- Hold carburetor in vise at idle screw boss. Place dial indicator with 40 mm extension over pump plunger. Measure travel from full closed to full open throttle. Plunger travel should be 0.265" (6.7 mm).