Jaguar & Triumph
Disconnect negative battery cable and air flow meter connector. Connect ohmmeter leads to terminals 6 and 27 on potentiometer connector. Readings should be as follows. If not, replace temperature sensor and air flow meter as an assembly.
Temperature/Resistance Relationship Jaguar & Triumph
| Temperature | Resistance (Ohms) |
|---|---|
| 14°F (-10°C) | 9, 200 |
| 32°F (0°C) | 5, 900 |
| 68°F (20°C) | 2, 500 |
| 104°F (40°C) | 1, 180 |
| 140°F (60°C) | 600 |