Parts Replacement & Testing: Bushings
Self-lubricating bushings should be replaced only when worn or damaged. Force out bushings, using a suitable mandrel, remove burrs and clean hole. Before pressing in new bushing, soak bushing in a suitable oil for not less than 30 minutes. After replacing, cross check inner diameter of bushing by pulling a smoothing mandrel through.