Inspection [11/2020 - ]: Procedure
- INSPECT MASS AIR FLOW METER SUB-ASSEMBLY
- Perform a visual check for any foreign matter on the temperature sensor (thermistor) of the mass air flow meter sub-assembly shown in the illustration.
*a Thermistor OK
There is no foreign matter.
If the result is not as specified, replace the mass air flow meter sub-assembly.
- Measure the resistance according to the value(s) in the table below.
*a Component without harness connected
(Mass Air Flow Meter Sub-assembly)Standard Resistance
Tester Connection Condition Specified Condition Result 4 (THA) - 2 (E2G) -20°C (-4°F) 13.6 to 18.4 kΩ kΩ 4 (THA) - 2 (E2G) 20°C (68°F) 2.21 to 2.69 kΩ kΩ 4 (THA) - 2 (E2G) 60°C (140°F) 0.49 to 0.67 kΩ kΩ If the result is not as specified, replace the mass air flow meter sub-assembly.
- Perform a visual check for any foreign matter on the temperature sensor (thermistor) of the mass air flow meter sub-assembly shown in the illustration.