Knock Sensor: Inspection
- INSPECT KNOCK SENSOR
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
STANDARD RESISTANCE SPECIFICATION
| Tester Connection |
Condition |
Specified Condition |
| 1-2 |
20°C (68°F) |
120 k to 280 kΩ |
If the result is not as specified, replace the sensor.
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002