On-Vehicle Inspection
- DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL
- REMOVE CIRCUIT OPENING RELAY
- Remove the relay block cover upper.
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
- Remove the circuit opening relay.
- INSPECT CIRCUIT OPENING RELAY
- Check the resistance.
- Using an ohmmeter, measure the resistance between the terminals.
Standard resistance
STANDARD RESISTANCE
| Tester Connection |
Specified Condition |
| 3 - 5 |
10 kΩ or higher |
Below 1 Ω (Battery voltage applied to terminals 1 and 2) |
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
If the result is not as specified, replace the circuit opening relay.
- INSTALL CIRCUIT OPENING RELAY
- Install the circuit opening relay.
- Install the relay block cover upper.
- CONNECT CABLE TO NEGATIVE BATTERY TERMINAL
Torque: 3.9 N*m (40 kgf*cm, 35 in.*lbf)