Disposal Accumulator

  1. Remove the accumulator from the HPU.
  2. Place the accumulator in a vise.
  3. Using a saw, discharge the gas inside by making a hole in the hatching area.
CAUTION:
  • The gas discharging is colorless, odorless and harmless.
  • Saw a hole while covering the saw with a shop rug because chips may fly up.>
Fig 1: Identifying Hatching Area
G00928249Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002