CHARGING SYSTEM SERVICE DATA (GENERATOR)
| Application |
Specification |
| Rated Output |
12 Volts/90 Amps, 100 Amps |
| Rotor Coil resistance @ 68°F (20°C) |
| 90 Amp |
2.1-2.5 Ohms |
| 100 Amp |
2.7-3.1 Ohms |
| Slip Ring Diameter |
| Standard |
.559-0.567 in. (14.2-14.4 mm) |
| Minimum |
.504 in. (12.8 mm) |
| Brush Exposed Length |
| Standard |
.374-.453 in. (9.5-11.5 mm) |
| Minimum |
.059 in. (1.5 mm) |
GENERATOR REGULATED OUTPUT SPECIFICATIONS
| Application |
Amps |
Volts |
| Regulating Voltage |
10 Or Less |
13.2-14.8 |