September 30: LEMON manuals is back up on a temporary server! Slowness is possible
Distributor Sensors
DISTRIBUTOR PICK-UP COIL AIR GAP
| Application |
In. (mm) |
| Land Cruiser, LX450 |
.008-.016 (.20-.40) |
DISTRIBUTOR PICK-UP COIL RESISTANCE
| Pick-Up Coil Terminals |
Ohms |
| Cold (14-122°F (-10-50°C)) |
| G1 & G- |
185-275 |
| G2 & G- |
185-275 |
| NE & G- |
185-275 |
| Hot (122-212°F (50-100°C)) |
| G1 & G- |
240-325 |
| G2 & G- |
240-325 |
| NE & G- |
240-325 |
CRANKSHAFT POSITION SENSOR RESISTANCE
| Application |
Ohms |
| Cold (14-122°F (-10-50°C)) |
1630-2740 |
| Hot (122-212°F (50-100°C)) |
2065-3225 |