Turn Signal and Hazard Warning Relay Inspection
Reference: TURN SIGNAL AND HAZARD WARNING RELAY REMOVAL AND INSTALLATION
- Connect turn signal and hazard warning relay (1), battery (2) and six test bulbs ((12 V, 21 W) (3) and 12 V, 5 W (4)) as shown.
- Check turn L circuit
Connect terminal "5" and battery negative (-) terminal by a jumper wire.
Check left side bulbs (1) for flashing cycle.
If check result is not as specified, replace turn signal and hazard warning relay.
Reference flashing cycle
60 - 120 cycle/minute
- Check turn R circuit
Connect terminal "6" and battery negative (-) terminal by a jumper wire.
Check right side bulbs (1) for flashing cycle.
If check result is not as specified, replace turn signal and hazard warning relay.
Reference flashing cycle
60 - 120 cycle/minute
- Check Hazard ON circuit
Connect terminal "8" and battery negative (-) terminal by a jumper wire.
Check all bulbs (1) for flashing cycle.
If check result is not as specified, replace turn signal and hazard warning relay.
Reference flashing cycle
60 - 120 cycle/minute