Temperature Control Actuator Inspection
Reference: TEMPERATURE CONTROL ACTUATOR REMOVAL AND INSTALLATION
- Set arm to actuator and check if arm operates smoothly when battery voltage is conducted to terminals of actuator connector (1).
Courtesy of SUZUKI OF AMERICA CORP.
- Using ohmmeter, measure resistance between "3" terminal and "5" terminal of actuator connector (1) at each arm position.
Temperature control actuator resistance
Driver side
RESISTANCE REFERENCEArm position Resistance (25 °C (77 °F)) MAX COOL [a] Approx. 0.62 kΩ MAX HOT [b] Approx. 5.38 kΩ Passenger side
RESISTANCE REFERENCEArm position Resistance (25 °C (77 °F)) MAX COOL [a] Approx. 5.38 kΩ MAX HOT [b] Approx. 0.62 kΩ - Using ohmmeter, measure resistance between "4" terminal and "5" terminal.
Temperature control actuator resistance (Total resistance)
6 kΩ (Driver side and passenger side)
Fig 4: Measuring Resistance Between Terminals Of Actuator Connector At Each Arm Position (Passenger Side)
If check result is not as specified, replace temperature control actuator.